attention

  • PROVA-803, Digital Multi-Meter

PROVA- 801/803 Digital Multi-Meter

  • count and dual input channels
  • 0.04% DC basic accuracy and 0.2% AC basic accuracy
  • Bandwidth of 10KHz(max)
  • Fast ACV, ACA response
  • Dual channels measurement similar to a dual channels DSO( V+V , V+A)
  • Hz + duty cycle dual display
  • Capacitance measurement
  • Standalone data logging of 10,708 records for both channels(803)
  • RS-232C interface
  • Application Software (Option)
  • 1/7 the cost

 


 

 

The following accuracy is specified for one single channel (channel 1 or channel 2). If dual channels are used at the same time, additional % of accuracy should be added to the listed accuracy. Please refer to the supplemental dual channels specification. The following accuracy is also specified for the ZEROED (relative) value. The accuracy is given as ±% of reading ± number of least significant digits.

 

 

Range

Resolution

Beeper

Overload Protection

999.99 Ω

0.01 Ω

< 40 Ω ( approx )

AC 1000V

 

Frequency : (TTL) (Overload Protection AC 1000V)

 

 

Range ( Auto )

Resolution

Accuracy

1.000Hz -2MHz

0.0001Hz - 0.0001MHz

±0.005%±4dgts

 

DC Voltage: (Input Impedance: 10MΩ )(Overload Protection DC 1000V)

 

 

Range

Resolution

Accuracy

60.000mV

0.001mV

±0.2%±9dgts

600.00mV

0.01mV

±0.04%±6dgts

6.0000V

0.0001V

±0.04%±6dgts

60.000V

0.001V

±0.04%±6dgts

600.00V

0.01V

±0.04%±6dgts

1000.0V

0.1V

±0.08%±6dgts

 

DC Current: (10A terminal is protected by a 20A fast blown, high energy fuse, and the terminal of μ A and mA is protected by 1A fast blown, high energy fuse )

 

 

Range

Resolution

Accuracy

600.00 μ A

0.01 μ A

±0.4%±20dgts

6000.0 μ A

0.1 μ A

±0.2%±20dgts

60.000mA

0.001mA

±0.4%±20dgts

600.00mA

0.01mA

±0.2%±20dgts

1.0000A

0.0001A

±0.2%±20dgts

10.000A 1

0.001A

±0.6%±20dgts

 

Diode Test : (open voltage 3V approx. overload protection AC 1000V)

 

 

Range

Resolution

Accuracy

Short Circuit Current

3.0000V

0.0001V

±2%±5dgts

0.8 mA typical

 

Duty Cycle : (%, TTL, 1Hz – 600KHz) (Overload Protection AC 1000V)

 

 

Range

Resolution

Accuracy

0.001% - 9.999%

0.001%

±30d/KHz±30dgts

10.00% - 100.00%

0.01%

±3d/KHz±3dgts

 

Resistance: ( Ω )

 

 

Range

Resolution

Accuracy

Overload Protection

999.99 Ω

0.01 Ω

±0.25%±9dgts

AC 1000V

9.9999K Ω

0.0001K Ω

±0.15%±6dgts

AC 1000V

99.999K Ω

0.001K Ω

±0.15%±6dgts

AC 1000V

999.99K Ω

0.01K Ω

±0.15%±6dgts

AC 1000V

9.9999M Ω

0.0001M Ω

±0.3%±9dgts

AC 1000V

40.000M Ω

0.001M Ω

±1.5%±9dgts

AC 1000V

 

Capacitance: ( , auto range , and for film capacitor or better)

 

 

Range

Resolution

Accuracy 1

60.00nF

0.01nF

±1.2%±8dgts

600.0nF

0.1n F

±2.5%±8dgts

6.000 μ F

0.001 μ F

±2.5 %±8dgts

60.00 μ F

0.01 μ F

±3.0%±8dgts

600.0 μ F

0.1 μ F

±5.0%±8dgts

 

AC Voltage: The accuracy of ACV or AC mV is specified for 5%-100% of range from 20Hz-10KHz, average sensing. Input Impedance is 10M Ω , and overloaded protection is AC 1000V for all range. Accuracy is also specified for single channel (channel 1 or channel 2). If dual channels measurements are performed, additional specification of accuracy will be introduced. Please refer to the supplemental dual channels specification. Due to the wide bandwidth, the reading might not be zero when no inputs present. But the residual reading does not affect the listed accuracy. If the AC reading is less than 100 least significant counts, it is set to zero by the un it.

 

 

Range

(ACV)

 

 

Resolution

 

 

Accuracy

(50/60Hz)

 

 

Accuracy

(45Hz - 1KHz)

 

 

Accuracy

(20Hz - 45Hz)

 

 

Accuracy (1KHz-10KHz)

60.000mV

0.001mV

±0.2%±40dgts

±0.6%±40dgts

±1.6%±50dgts

±4%±40dgts

600.00mV

0.001mV

±0.2%±40dgts

±0.6%±40dgts

±1.6%±50dgts

±2%±40dgts

6.0000V

0.01mV

±0.2%±40dgts

±0.6%±40dgts

±1.6%±50dgts

±2%±40dgts

60.000V

0.0001V

±0.2%±40dgts

±0.6±40dgts

±1.6%±50dgts

±2%±40dgts

600.00V (0-400V)

0.001V

±0.2%±40dgts

±1.0%±40dgts

±1.6%±50dgts

±9%±40dgts

600.00V (400-600V)

0.01V

±0.2%±40dgts

±1.0%±40dgts

±1.6%±50dgts

Not Specified

1000.0V (0-400V)

0.1V

±0.2%±40dgts

±4%±60dgts

±1.6%±50dgts

±4%±80dgts

1000.0V (400-1000V)

0.1V

±0.2%±40dgts

(45Hz - 400Hz) ±4%±60dgts

±1.6%±50dgts

Not Specified

 

Supplemental Dual Channels Specification (DC – 400Hz): The following accuracy should be added to all the listed accuracy if dual channels measurements are performed.

 

 

 

ACV (Ch2)

DCV (Ch2)

ACA (Ch2)

DCA (Ch2)

ACV (Ch1)

±2%±( V1 - V2 )* 200 PPM (Ch1, Ch2)

±0.9%±(V1 - V2) * 20PPM (Ch1, Ch2)

±0. 2 μ A / V( μ A,Ch2)

± 2 μ A / V (mA,Ch2)

±0.4mA / V (A, Ch2)

±4mV / A (mV, Ch1)

± 9mV / A (V, Ch1)

 

±0.5% (Ch1, Ch2)

DCV (Ch1)

±0.9%±(V1 - V2) * 20 PPM (Ch1, Ch2)

±0.5% (Ch1,Ch2

±0.5% (Ch1, Ch2)

±0.5% (Ch1, Ch2)

 

AC Current: (The accuracy is specified for a single channel for 5%-100% of range for 45Hz – 10KHz,average sensing, , 10A terminal is protected by a 20A fast blown, high energy fuse, and the terminal of μ A and mA is protected by 1A fast blown, high energy fuse. If the AC reading is less than 100 least significant digits, it is set to zero by the unit )

 

 

Range (ACA)

Resolution

Accuracy (50/60Hz)

Accuracy (45Hz - 1KHz)

Accuracy (20Hz - 45Hz)

Accuracy (1KHz -10KHz)

600.00 μ A

0.01m A

±0.6%±40dgts

±0.8%±40dgts

±2%±20dgts

±4%±20dgts

6000.0 μ A

0.1m A

±0.6%±40dgts

±0.8%±40dgts

±2%±20dgts

±4%±20dgts

60.000mA

0.001mA

±0.6%±40dgts

±0.8%±40dgts

±2%±20dgts

±0.9%±20dgts

600.00mA

0.01mA

±0.6%±40dgts

±0.8%±40dgts

±2%±20dgts

±0.9%±20dgts

1.0000A

0.0001A

±0.6%±40dgts

±0.8%±40dgts

±2%±20dgts

±2.5%20dgts

10.000A 1

0.001A

±0.9%±40dgts

±0.9%±40dgts

±3.9%±20dgts

±2.5%20dgts

 

 

 

 

 

Range

(ACA)

 

 

Accuracy

(20Hz - 45Hz)

 

 

Accuracy

(1KHz – 10KHz)

 

 

Accuracy

(10KHz – 20KHz)

 

 

600.00 μ A

±1%±20dgts

<

Write a review

Note: HTML is not translated!
   Bad           Good
Captcha

PROVA-803, Digital Multi-Meter

  • Brands TES
  • Product Code:PROVA 803
  • Availability:In Stock
  • 114,000,000ریال


Related Products

 Digital Multimeterr, Hioki DT4252

Digital Multimeterr, Hioki DT4252

Capacitance, and Frequency 1000V, 5 Range Digital Multimeterr Hioki DT4252 ..

0ریال

OWON OW18B Digital Multimeter Bluetooth Data Logger

OWON OW18B Digital Multimeter Bluetooth Data Logger

OWON OW18B Smart Digital Multimeter with Bluetooth Specifications Main Feature..

31,000,000ریال

OWON OW18D/E 4 1/2 Digits Handheld Digital Multimeter

OWON OW18D/E 4 1/2 Digits Handheld Digital Multimeter

OWON OW18D/E 4 1/2 Digits Handheld Digital Multimeter + 4 1/2 bit resolution (2000..

44,000,000ریال