The DMM to replace your bench-top one
-
0.02% DC and 0.1% AC basic accuracy
-
60,000 counts resolution
-
200KHz (max.) bandwidth
-
True RMS with fast ACV/ACA response
-
Dual channels measurement similar to a dual channels DSO (V+V, V+A)
-
RS-232C ASCII interface
-
Data logging (model 903 with 10,708 records for both channels)
-
Capacitance measurement
-
Free software (901,903)
-
1/3 the cost
Electrical Specifications: (23℃±5℃) |
|
|
The following accuracy is specified for one single channel (channel 1 or channel 2). |
|
If dual channels are used at the same time, additional % of accuracy should be added to the listed accuracy. |
Please refer to the supplemental dual channels specification. |
|
|
The following accuracy is also specified for the ZEROED (relative) value. |
|
The accuracy is given as ±% of reading ± number of least significant digits. |
|
AC Voltage: |
|
|
|
|
Range (ACV) |
Resolution |
Accuracy (50/ 60Hz) |
Accuracy (45Hz – 1KHz) |
|
60.000mV |
0.001mV |
±0.1%±20dgts |
±0.3%±20dgts |
|
600.00mV |
0.01mV |
±0.1%±20dgts |
±0.3%±20dgts |
|
6.0000V |
0.0001V |
±0.1%±20dgts |
±0.3%±20dgts |
|
60.000V |
0.001V |
±0.1%±20dgts |
±0.6%±20dgts |
|
600.00V |
0.01V |
±0.1%±20dgts |
±0.6%±20dgts |
|
1000.0V (0-400V) |
0.1V |
±0.1%±20dgts |
±2%±30dgts |
|
1000.0V (400-1000V) |
0.1V |
±0.1%±20dgts |
(45Hz – 400Hz) ±2%±30dgts |
|
|
|
|
|
|
Range |
Accuracy |
Accuracy |
Accuracy |
|
(ACV) |
(20Hz - 45Hz) |
(1KHz– 10KHz) |
(10KHz– 20KHz) |
|
60.000mV |
±0.8%±25dgts |
±2%±20dgts |
±2.5%±20dgts |
|
600.00mV |
±0.8%±25dgts |
±1%±20dgts |
±2.5%±20dgts |
|
6.0000V |
±0.8%±25dgts |
±1%±20dgts |
±2.0%±20dgts |
|
60.000V |
±0.8%±25dgts |
±1%±20dgts |
±2.0%±20dgts |
|
600.00V (0-400V) |
±0.8%±25dgts |
±5%±20dgts |
Not Specified |
|
600.00V (400-600V) |
±0.8%±25dgts |
Not Specified |
Not Specified |
|
1000.0V (0-400V) |
±0.8%±25dgts |
±2%±40dgts |
Not Specified |
|
1000.0V (400-1000V) |
±0.8%±25dgts |
Not Specified |
Not Specified |
|
|
|
|
|
|
Range |
Accuracy |
Accuracy |
Accuracy |
|
(ACV) |
(20KHz – 50KHz) |
(50KHz– 100KHz) |
(100KHz-200KHz) |
|
60.000mV |
±4%±40dgts |
±4%±40dgts |
Not Specified |
|
600.00mV |
±2%±40dgts |
±2%±40dgts |
±2%±40dgts |
|
6.0000V |
±2%±40dgts |
±2%±40dgts |
±2%±40dgts |
|
60.000V |
±4%±40dgts |
±4%±40dgts |
Not Specified |
|
600.00V |
Not Specified |
Not Specified |
Not Specified |
|
1000.0V |
Not Specified |
Not Specified |
Not Specified |
|
|
|
|
|
|
DC Voltage: (Input Impedance: 10M*) |
|
|
|
Range |
Resolution |
Accuracy |
Overload Protection |
|
60.000mV |
0.001mV |
±0.1%±5dgts |
DC 1000V |
|
600.00mV |
0.01mV |
±0.03%±3dgts |
DC 1000V |
|
6.0000V |
0.0001V |
±0.03%±3dgts |
DC 1000V |
|
60.000V |
0.001V |
±0.03%±3dgts |
DC 1000V |
|
600.00V |
0.01V |
±0.03%±3dgts |
DC 1000V |
|
1000.0V |
0.1V |
±0.04%±3dgts |
DC 1000V |
|
|
|
|
|
|
AC Current: |
|
|
|
|
Range (ACA) |
Resolution |
Accuracy (50/60Hz) |
Accuracy (45Hz – 1KHz) |
|
600.00μA |
0.01μA |
±0.3%±20dgts |
±0.4%±20dgts |
|
6000.0μA |
0.1μA |
±0.3%±20dgts |
±0.4%±20dgts |
|
60.000mA |
0.001mA |
±0.3%±20dgts |
±0.4%±20dgts |
|
600.00mA |
0.01mA |
±0.3%±20dgts |
±0.4%±20dgts |
|
1.0000A |
0.0001A |
±0.3%±20dgts |
±0.4%±20dgts |
|
10.000A |
0.001A |
±0.5%±20dgts |
±0.4%±20dgts |
|
|
|
|
|
|
Range (ACA) |
Accuracy |
Accuracy |
Accuracy |
|
(20Hz - 45Hz) |
(1KHz – 10KHz) |
(10KHz – 20KHz) |
|
600.00μA |
±1%±20dgts |
±2%±20dgts |
±1%±20dgts |
|
6000.0μA |
±1%±20dgts |
±2%±20dgts |
±1%±20dgts |
|
60.000mA |
±1%±20dgts |
±0.5%±20dgts |
±1%±20dgts |
|
600.00mA |
±1%±20dgts |
±0.5%±20dgts |
±1%±20dgts |
|
1.0000A |
±1%±20dgts |
±1.5%±20dgts |
Not Specified |
|
10.000A |
±2%±20dgts |
±1.5%±20dgts |
Not Specified |
|
|
|
|
|
|
DC Current: |
|
|
|
|
Range |
Resolution |
Accuracy |
|
|
600.00μA |
0.01μA |
±0.2%±10dgts |
|
|
6000.0μA |
0.1μA |
±0.1%±10dgts |
|
|
60.000mA |
0.001mA |
±0.2%±10dgts |
|
|
600.00mA |
0.01mA |
±0.1%±10dgts |
|
|
1.0000A |
0.0001A |
±0.1%±10dgts |
|
|
10.000A |
0.001A |
±0.3%±10dgts |
|
|
|
|
|
|
|
Supplemental Dual Channels Specification (DC–400Hz): |
|
The following accuracy should be added to all the listed accuracy if dual channels measurements are performed. |
|
ACV (Ch2) |
DCV (Ch2) |
ACA (Ch2) |
DCA (Ch2) |
ACV |
±1% |
±0.5% |
±0.1μA/ V (μA,Ch2) |
±0.25% |
(Ch1) |
± (V1 – V2) |
± (V1 – V2) |
±1μA / V (mA,Ch2) |
(Ch1, Ch2) |
|
* 200 PPM |
* 20 PPM |
±0.2mA / V (A, Ch2) |
|
|
(Ch1, Ch2) |
(Ch1, Ch2) |
±2mV / A (mV, Ch1) |
|
|
|
|
±5mV / A (V, Ch1) |
|
DCV |
±0.5% ± (V1 – V2) |
±0.25% |
±0.25% |
±0.25% |
(Ch1) |
* 20 PPM |
(Ch1, Ch2) |
(Ch1, Ch2) |
(Ch1, Ch2) |
|
(Ch1, Ch2) |
|
|
|
The result of (V1-V2) * PPM is of volts. |
|
|
|
V1: the voltage reading in volts of channel 1 |
|
|
|
V2: the voltage reading in volts of channel 2 |
|
|
|
PPM: parts per million, Ch1: Channel 1, Ch2: Channel2 |
|
|
|
|
|
|
|
Resistance: (Ω) |
|
|
|
|
Range |
Resolution |
Accuracy |
Overload Protection |
|
999.99Ω |
0.01Ω |
±0.19%±8dgts |
AC 1000V |
|
9.9999KΩ |
0.0001KΩ |
±0.39%±3dgts |
AC 1000V |
|
99.999KΩ |
0.001KΩ |
±0.39%±3dgts |
AC 1000V |
|
999.99KΩ |
0.01KΩ |
±0.19%±3dgts |
AC 1000V |
|
9.9999MΩ |
0.0001MΩ |
±0.2%±6dgts |
AC 1000V |
|
40.000MΩ |
0.001MΩ |
±1%±6dgts |
AC 1000V |
|
|
|
|
|
|
|
(open voltage 3V approx.) |
|
|
Range |
Resolution |
Beeper |
Overload Protection |
|
999.99Ω |
0.01Ω |
< 40Ωapprox. |
AC 1000V |
|
|
|
|
|
|
|
( auto range, and for film capacitor or better) |
|
Range |
Resolution |
Accuracy |
|
|
60.00nF |
0.01nF |
±0.8%±5dgts |
|
|
600.0nF |
0.1nF |
±1.5%±5dgts |
|
|
6.000μF |
0.001μF |
±1.5%±5dgts |
|
|
60.00μF |
0.01μF |
±2.0%±5dgts |
|
|
490.0μF |
0.1μF |
±3.5%±5dgts |
|
|
|
|
|
|
|
|
(manual range, and for film capacitor or better) |
|
|
Range |
Resolution |
Accuracy |
|
|
99.99nF |
0.01nF |
±0.8%±5dgts |
|
|
999.9nF |
0.1nF |
±1.5%±5dgts |
|
|
9.999μF |
1μF |
±1.5%±5dgts |
|
|
99.99μF |
0.01μF |
±2.0%±5dgts |
|
|
999.9μF |
0.1μF |
±3.5%±5dgts |
|
|
|
|
|
|
|
Diode Test:(Diode)(open voltage 3V approx., overload protection AC 1000V) |
|
Range |
Resolution |
Accuracy |
Short Circuit Current |
|
3.0000V |
0.0001V |
±2%±5dgts |
0.8 mA typical |
|
|
|
|
|
|
Frequency:(TTL) |
|
|
|
|
Range (Auto) |
Resolution |
Accuracy |
Overload Protection |
|
1.000Hz – 2MHz |
0.0001Hz–0.0001MHz |
±0.005%±4dgts |
AC 1000V |
|
|
|
|
|
|
Duty Cycle:(%, TTL, 1Hz – 600KHz) |
|
|
|
Range |
Resolution |
Accuracy |
Overload Protection |
|
0.001% - 9.999% |
0.00% |
±30d/KHz±30dgts |
AC 1000V |
|
10.00% – 100.00% |
0.01% |
±3d/KHz±3dgts |
AC 1000V |
|
|
|
|
|
|
Frequency: (AC sine wave) |
|
|
|
Range |
Resolution |
Accuracy |
Overload Protection |
|
1.0000Hz– 200KHz |
0.0001Hz–100Hz |
±0.02%±4dgts |
AC 1000V |
|
|
|
|
|
|
Duty Cycle: (%, Sine Wave) |
|
|
|
Range |
Resolution |
Accuracy |
Overload Protection |
|
0.001% – 100.00% |
0.001% – 0.01% |
Not specified |
AC 1000V |
|
|
|
|
|
|
General Specifications: |
|
|
|
Battery Type: |
9V |
|
|
Fuse: |
Fast 20A/1000V (A terminal) |
|
|
Fast 1A/1000V (mA / μA terminal) |
|
|
Display: |
5 + 5 digits LCD |
|
|
with 30 segments bar graph |
|
|
Range Selection: |
auto and manual |
|
|
Overload Indication: |
OL |
|
|
&
PROVA 901,PROVA903, Digital Multi-Meter
- Brands Prova
- Product Code: PROVA 903
- Availability: In Stock
Related Products
TES-2900 True RMS MULTIMETER
Variable - frequency drive (VFD) V & Hz measurement.&..
83,000,000ریال
Capacitance, and Frequency
1000V, 5 Range Digital Multimeterr
Hioki DT4252
..
0ریال
Auto range muitimeter, kyoritsu1009
Auto range and manual range selector provided.
..
0ریال
OWON OW18B Smart Digital Multimeter with Bluetooth
Specifications
Main Feature..
31,000,000ریال
OWON OW18D/E 4 1/2 Digits Handheld Digital Multimeter
+ 4 1/2 bit resolution (2000..
44,000,000ریال
Manufacturer: OWON
Model: OW18C
Origin: China
Warranty: 12 months
..
14,000,000ریال
OWON 3 5/6 NCV Digital Multimeter OW16
+ 3 5/6 bit resolution
+ D..
12,600,000ریال
OWON OW18 Series 3 5/6 Smart Digital Multimeter
+ 3 5/6 bit resolution
+ Data L..
18,000,000ریال
|